It is my pleasure to announce that we have started the production of Cool Touch coolers of new V3 version. The announcement can also be found of our website, by logging in with the password you were given.
Change log for CHA and CHS coolers:
1) New much improved solenoid valve.
a. New solenoid body, complete/whole. No more solenoids falling out.
b. New material. Much better for hot water – no more boiled solenoids.
c. New material for high pressure solenoid valve, which improves the behavior.
d. Improved structure (position of high pressure solenoid is changed + internal improvements) of whole solenoid block – much better and prettier flow of sparkling water from solenoid and into cup.
e. One solenoid block is now used for both CHA and CHS coolers - easier stock management, easier upgrade (in future) from CHA to CHS.
f. Cleaning/fixing process – it is possible to remove the power part of each individual solenoid and clean/change insides.
2) Removed metal spring that helped to hold old solenoids inside the body.
3) New solenoids are available for purchase starting from end of august – for changing on all existing CHS coolers. Unfortunately, it is impossible to change solenoid base on old CHA coolers (metal pipe that supplied water from cold tank to ambient solenoid is in the way).
Additional change log for CHS coolers:
1) New control and power PCB (from CHA/03/Extra/Easy coolers).
a. Now both CHS and CHA coolers share the same PCB, wires, tanks, solenoids. Upgrade from BOU to POU, or from CHA to CHS is very simple now (for future planning, etc).
b. New control (touch sensor) PCB is more reliable in terms of touch controls. No more coolers where water started to flow by itself.
c. New power PCB is much more reliable then old relay system. Now, no more problems with burnt out relays.
d. New coolers have fixed an old software issue (was impossible to fix on old PCB): when POU coolers started showing Call Service/replace filter command two weeks early. Now it is shown only after 6 months. Another issue fixed in this update – very rare problem when cooler with no gas operating for very long time (several months without restart) would show Call Service error (you had to restart cooler, very rare issue, probably no clients experienced).
e. Because new (CHA) control PCB did not allow for USS sensor – an external, new USS PCB was developed.
i. It is a bit better at filtering events (like house shaking, radio waves, air currents) than old system – it will turn on cooler less than old USS sensor.
ii. It will, however, work worse when several coolers stand together – potentially changing brightness because of interference from neighbor USS sensors. This will be fixed in Cool Touch 04 PCB – early next year.
iii. New settings for recalibration of USS behavior (if coolers sees something close to it (it shows bright light and ozone generator is powered on) for more than 30 minutes – it will try to recalibrate itself (and should power off if there is no one else, and its just an issue with vibrations, air currents - “false positive events”).
f. Several updates to stability and operation of Ozone generator (introduced maximum ON time, for example):
i. No more sound of ozone generator for longer than 60 seconds + 60 seconds off time between two ON events, in order to preserve ozone generators and human ears (noise).
g. As CT3 PCB comes with beeper (to show when it is time to change defective bottle).