On 12.05.16 a new firmware has been released for Cool Touch coolers based on CT3 (Basic) platform. Models affected are CTB/P-03x-CHS/A. We strongly recommend to update all coolers to new firmware and use the new functionality.
Changelog:
New:
1) New feature - ozone sterilisation of whole cooler. It is accessible from service menu by pressing hot button twice (once to enter sterilisation menu, twice to start).
Using new feature: cooler has to be completely empty - no water left in cold or hot tanks. Sterilisation takes about 2 - 6 minutes. The finger and tap should be connected by silicone tube in order to avoid ozone spillage into the air - please contact SIG to get free tubes. The process sterilises hot and cold tanks, hot/cold/ambient tubes and hot/cold/ambient solenoid valves, tap and finger. This process can be done after cleaning cooler at the service base, or at clients, as its absolutely harmless and looks professional. We recommend doing sterilisation at clients before setting new cooler and every 6 months.
Fixed for POU coolers:
1) No Water state and operation completely reviewed
2) Water quality settings moved to programming mode
3) Indication behavior in service and programming modes aligned
4) Coffee refill, updated to be running from unit tanks
The firmware can be downloaded from here, or from server.